검색 상세

이젝터 구동용 냉각기의 열교환 성능 특성에 관한 연구

A Study on the Heat Exchanger Performance Characteristics of Cooling System by Ejector,

이윤환 (Lee, Youn Hwan, 경상대학교 대학원)

원문보기

  • 주제(키워드) 이젝터 , 디퓨져 , 열교환기
  • 발행기관 경상대학교 대학원
  • 지도교수 정한식
  • 발행년도 2006
  • 학위수여년월 2006. 8
  • 학위명 박사
  • 소속대학원 및 학과 대학원 정밀기계공학과
  • 전공 열유체공학
  • 원문페이지 xix, 228
  • 본문언어 한국어
초록/요약moremore
In this research, we studied on the design, the development and performance evaluation for the water and steam ejector, and we developed through the optimum design for each ejector. Also, we studied the numerical analysis for water and steam ejector and obtained the optimum conditions to increase th...
In this research, we studied on the design, the development and performance evaluation for the water and steam ejector, and we developed through the optimum design for each ejector. Also, we studied the numerical analysis for water and steam ejector and obtained the optimum conditions to increase the efficiency of ejector. 1. T-type ejector is showed the good performance in case of T-1 than other cases at the same flux (T-1>T-2>T-3). Until the driving time about 60 minutes the pressure is smaller difference each, after 60 minutes the pressure is showed similar performance. Then the finally pressure is indicated about 45mmHg. 2. The efficiency increase of ejector that the diffuser is large is high above about 40% the ratio of pressure drop by using strut at the outlet of diffuser. 3. We showed that the swirl intensity of forced vortex type, inserting core and inserting strut in the diffuser center of ejector can cause a rising pressure recovery by numerical analysis. 4. The ejector performance by numerical analysis is recorded to the improved 6% by the air for working fluid. This is why the flow control is so important and effective. 5. The temperature drop into vacuum tank is shown high in case of air part than water part, but the calorie is shown high amount of 363.47 times in case of water due to the water has the high specific weight and specific heat at constant volume then air. So, the working fluid is used water in this system to increase the effect of heat transfer. 6. The temperature in vacuum tank is rapidly increased at the contact part with air, but it is no affected to the efficiency of heat exchanger. So, the efficiency of heat exchanger very good over 90%. 7. The maximum calorie is appeared 1,620 Kcal/hr in case of test 6, the others is indicated about 1,440 Kcal/hr. This system can be rise the efficiency about 20~30% by increasing the evaporated area.
목차moremore
Ⅰ. 서론 1
1.연구의 필요성 1
2. 연구 동향 4
...
Ⅰ. 서론 1
1.연구의 필요성 1
2. 연구 동향 4
3. 연구 목적 6
Ⅱ. 이론 8
1. 일반 이론 8
2. 이젝터의 종류와 특징 12
3. 냉각기용 열교환기의 종류와 특징 15
Ⅲ. 수이젝터의 실험 18
1. T형 이젝터 설계 및 개발 18
2. B형 이젝터 설계 및 개발 25
3. 이젝터 성능 실험 장치 35
4. 성능 실험 37
5. 실험 결과 46
Ⅳ. 수이젝터의 성능 해석 88
1. 연구목적 88
2. 디퓨져의 압력회복 이론 90
3. 수치해석 모델 92
4. 수치해석 기법 93
5. 수치해석 96
6. 수치해석 결과 105
Ⅴ. 수이젝터의 유동제어에 의한 성능 해석 106
1. 이론적 배경 106
2. 연구목적 113
3. 디퓨져 모델 113
4. 수치해석 기법 118
5. 수치해석 123
6. 성능 해석 결과 151
Ⅵ. 냉각기용 열교환기 특성 실험 153
1. 저진공 메카니즘의 이젝터 기본 설계 153
2. 저압 탱크의 용량별 진공도 최적 선도 설계 155
3. 저진공 밀폐식 증발형 용기 모델 설계 157
4. 강도 계산 164
5. Cylindrical shell의 두께 계산 166
6. 구조해석 170
7. 스팀 보일러의 용량 산정 180
8. 실험장치 구성 및 설계 183
9. 실험방법 188
10.실험 결과 및 고찰 190
Ⅶ. 결론 219
참고문헌 221
연구실적 226